For LED statuses please see: Iridium GO! exec - LED Status Indicators
System Errors and Warnings
Any current system errors and warnings that are detected by the Iridium GO! exec will be captured
under the "System Errors and Warnings" menu. To access the menu:
On the exec device touchscreen UI: Select Settings > System Errors and Warnings
Post Errors
The Iridium GO! exec performs a Power On Self Test during power on events. The table below is a summary of the errors that may be detected. Any errors will then be visible in the Post Errors menu item.
On the exec device touchscreen UI: Select About > Post errors
Warnings and System/Post Errors
Error Code | Category | Issue |
Error 100 | Battery Temperature | The Device Battery temperature is critically high (> 60deg C). The Device will power off automatically. Note: Once the device has powered off automatically due to the device battery temperature is critically high, for safety reason, the device cannot be powered on unless the device battery temperature drops below 58 C |
Error 101 | Battery Temperature | The Device Battery temperature is critically low (< -20deg C). The Device will power off automatically. |
Warning 102 | Battery Temperature | The Device Battery temperature is approaching the maximum allowed level at which point the Device will power off automatically. Move the Device to a cooler location to avoid shutdown. |
Warning 103 | Battery Temperature | The Device Battery temperature is approaching the minimum allowed level at which point the Device will power off automatically. Move the Device to a warmer location to avoid shutdown. |
Error 104 | Battery Temperature | An internal Error has occurred. If the error persists over a power cycle, contact support. |
Error 200 | Battery Level | The Device Battery level is critically low. The Device will power off automatically. |
Warning 201 | Battery Level | The Device Battery level is approaching the minimum allowed at which point the Device will power off automatically. |
Error 202 | Battery Level | An internal Error has occurred. If the error persists over a power cycle, contact support. |
Error 204 | Battery Level | An internal Error has occurred. If the error persists over a power cycle, contact support. |
Warning 300 | Battery Charging Temperature | The Device has stopped charging the Battery due to critically high Battery temperature. Move the Device to a cooler location to resume charging. |
Warning 301 | Battery Charging Temperature |
The Device has stopped charging the Battery due to critically low Battery temperature. Move the Device to a warmer location to resume charging |
Warning 302 | Battery Charging Temperature |
The Device Battery temperature is approaching the maximum allowed during charging at which point the Device will stop charging the Battery. Move the Device to a cooler location to continue successful charging. |
Warning 303 | Battery Charging Temperature |
The Device Battery temperature is approaching the minimum allowed during charging at which point the Device will stop charging the Battery. Move the Device to a warmer location to continue successful charging. |
Error 304 | Battery Charging Temperature |
An internal Error has occurred. If the error persists over a power cycle, contact support. |
Error 502 | Satellite modem temperature |
The Device Satellite modem temperature is critically high. The Device will power off automatically. Move the Device to a cooler location to resume operation. |
Error 503 | Satellite modem temperature |
The Device Satellite modem temperature is critically low. The Device will power off automatically. Move the Device to a warmer location to resume operation. |
Warning 504 | Satellite modem temperature |
The Device Satellite modem temperature is approaching the maximum allowed at which point the Device will power off automatically. Move the Device to a cooler location to continue successful operation. |
Warning 505 | Satellite modem temperature |
The Device Satellite modem temperature is approaching the minimum allowed at which point the Device will power off automatically. Move the Device to a warmer location to continue successful operation. |
Error 600 Internal device error |
Satellite modem temperature |
An internal hardware or software error has been detected. If possible, the user can try cycling the power or performing a factory reset of the device. If the error persists, please contact support. |
Error 601 | Satellite modem temperature |
The Device Satellite modem temperature is critically high. The Device will power off automatically. Move the Device to a cooler |
Error 602 | Satellite modem temperature |
The Device Satellite modem temperature is critically low. The Device will power off automatically. Move the Device to a warmer location to resume operation |
Error/warning 603 – 1050. Internal device error |
An internal hardware or software error has been detected. If possible, the user can try cycling the power or performing a factory reset of the device. If the error persists, please contact support. |
Comments